EasyManua.ls Logo

MIMAKI CG-160FXII - Examine the cut error [SAMPLE CUT]

MIMAKI CG-160FXII
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 3.23 –
Examine the cut error [SAMPLE CUT]
In the event where the data cannot be cut properly, the cause of abnormality is investigated cutting
the sample data stored in the equipment.
1. Press the [FUNCTION] key in the local mode.
2. With jog keys [ ] or [ ], select “SAMPLE
CUT.”
3. Press [ENTER/HOLD] key.
4. With jog keys [ ] or [ ], select sample data to
cut.
From the following 2 samples, select data to cut.
Proceed to the procedure 7 if “Cut” is selected and to the
procedure 5 if “LOGO” is selected.
Cut LOGO
  
5. With jog keys [ ] and [ ], select magnification
of sample data to cut. (when LOGO is selected)
You may select within the range of 1 to 999%.
6. Press [ENTER/HOLD] key to start cutting.
When sample cut is made, the data stored in the receiving
buffer of the equipment are deleted.
The result of Sample Cut
The sample data is cut properly but other data cannot be cut properly.
-> It is considered that abnormality exists on the host computer side.
Tthe sample data and other data cannot be cut properly.
-> Increase the set value of [Corrective Pressure Offset] (refer to the Operation Manual of the
equipment side) and increase the pressure when the cutter goes down.
SAMPLE CUT <ENT>
Cut <ent>
LOGO 100% <ent>
CUT1 **REMOTE**
FUNCTION

Table of Contents