Loading...
3-38
Change the operation condition of the room temperature
If you print in the status that the temperature of the place in which the machine has installed (room temper-
ature) is out of the usable temperature range, ink discharging defect or changing color may occur, and it
adversely affects the printing quality.
Here, select the operation if the room temperature is out of the usable temperature range when printing.
1
Press the key in the local
mode.
2
Select [MACHINE SETUP] by pressing
the keys.
3
Press the key.
4
Press to select
[ROOM TEMP.].
5
Press the key.
6
Press to select a set value.
Not wait ARR. : The error message is displayed for a moment, and printing starts.
Wait arrival : After the error message is displayed, wait until the room temperature
reaches the proper value. Then, printing starts.
7
Press the key.
Press the key several times to end the setting.
For the details of the usable temperature range, refer to P.6-3 “Available temp.”.
If the room temperature is out of the usable temperature range at the start of printing, the error
message below is displayed to inform you of it.
**** ERROR 120 ****
ROOM T EMP LOW ( XX ° C )
**** ERROR 121 ****
ROOM T EMP H I GH ( XX ° C )
* The temperature displayed in error message is the one of inside of the machine. Be careful that it is not actual
room temperature.
FUNCT I ON
SETUP <ENT>
FUNCT I ON
MACH I NE SE TUP < ENT >
MACH I NE SETUP
DEODOR I ZE FAN < e n t >
MACH I NE SETUP
ROOM TEMP . < e n t >
ROOM TEMP .
SEL :
N
ot wai t ARR.