4-31
Setting Routine operations
4
Routine Maintenance
Setting Pump tube washing interval in Standby mode
Perform the pump tube washing periodically to prevent ink from clogging due to the coagulation of ink,
which occurs within the tube.
1
Select [ROUTINE SETUP] of the maintenance menu.
(1) Press the key in the local mode.
(2) Select [MAINTENANCE] by pressing the keys then press the key.
(3) Select [ROUTINE SETUP] by pressing the keys.
(4) Press the key.
2
Select [PUMP TUBE WASH] by press-
ing the keys.
3
Press the key.
4
Set the tube washing interval by press-
ing the keys.
Set value : OFF, 1 - 168 hours
5
Press the key.
6
Press the key several times to end.
This function is operable only under the condition that the machine is left in the following dis-
plays.
When the cleaning solution has not been filled in the
machine, the right display is displayed at the step 5. Fill the
cleaning solution ( P.4-8) then redo the operations from
the step 1.
<LOCAL . 1> [#01] *REMOTE. 1* [ #01]
0.00m
LOCAL mode REMOTE mode
ROUT I NE SE TUP
PUMP TUBE WASH < e n t >
ROUT I NE SE TUP
WA S H I N T E R V A L =
1
h
ROUT I NE SE TUP
WA S H I N T E R V A L =
4
h
ROUT I NE SE TUP
PUMP TUBE WASH < e n t >
** Washing Liquid **