© 2011 MIMAKI ENGINEERING CO.,LTD. 5.1.10 P.1
1
2
3
4
5
6
7
8
R.1.0
5.1.10 [MOTOR TEST] PUMP MOTOR
Function
Operation test of pump motor is executed.
Operation Procedures
Step Item Description Remarks
1 Pump selection [], [] : Selects pump by moving the cursor.
[], [] : Selects operation.
[], [] :
Selection of items 1 – 3
2 Rotation direction
designation
[], [] : Selects pump rotation direction.
Set value: FORWARD, REVERSE
3 Driving speed designation [], [] : Selects driving speed.
Set value: 100 – 4000 pps (unit: 100 pps)
4 Carriage
/Motor state selection
[FUNCTION]:Carriage/motor state at test selection menu is
displayed.
<Carriage> IN: Executes at cap position.
OUT: Executes after carriage out.
<MOTOR> ON: Executes with Y-axis motor ON.
OFF: Executes with Y-axis motor OFF.
5 Test start [ENTER]: Removes the cap and moves the carriage to
maintenance position. Drives the pump motor with
designated conditions.
[END]: Ends the test.
During operation, open/
close the cartridge valve
with [FUNCTION].
6 End Test is completed.
Note that executing (FORWARD) while the cap is on causes vacuum suction.
MAINTENANCE MANUAL > Test Items > Test Function > [MOTOR TEST] PUMP MOTOR
Model
TS34-1800A
Issued
2011.10.17
Revised F/W ver
1.20
Remark
1.0