5.1.9 [MOTOR TEST] WIPER MOTOR
Function
Operation test of wiper motor is executed.
Operation Procedures
Step Item Description Remarks
1 Driving speed designation [], [] : Selects driving speed of the motor.
Set value: 100 – 4000 pps (unit: 100 pps)
[], [] :
Selection of items 1 – 3
2 WAIT designation [], [] : Designates operation interval.
Set value: 0 60 sec. (unit: 1 sec.)
3 Count designation [], [] : Designates No. of operation.
Set value: CONTINUE, 1 – 1000 count (unit: 1 count)
4 Test start [ENTER]: Drives the motor with designated conditions.
When CONTINUE is selected from the count
setting, press [END] to finish the test.
5 End Return the wiper to the original position.