© 2011 MIMAKI ENGINEERING CO.,LTD. 5.1.8 P.1
1
2
3
4
5
6
7
8
R.1.0
5.1.8 [MOTOR TEST] XY SERVO MOTOR
Function
Operation test of XY-axis motor is executed.
Operation Procedures
Step Item Description Remarks
1 X speed designation [], [] : Selects speed.
Set value: 1 – 500 mm/s (unit: 1 mm/s)
[], [] :
Selection of items 1 – 3
[ENTER]:
Transits to the Y direction
setting (5 –).
2 X acceleration designation [], [] : Selects acceleration.
Set value: 0.01 – 2.00 G (unit: 0.01 G)
3 X moving amount
designation
[], [] : Selects moving amount.
Set value: 1 mm – paper length (unit: 1 mm)
When media is not detected: 1 mm – 2500 mm
Press [ENTER] to start Y-axis motor setting.
4 Y speed designation [], [] : Selects speed.
Set value: 1 – 1500 mm/s (unit: 1 mm/s)
[], [] :
Selection of items 4 6
[ENTER]:
Transits to the following
step.
[END]: Transits to the X
direction setting (2 –).
5 Y acceleration designation [], [] : Selects acceleration.
Set value: 0.05 – 2.00 G (unit: 0.05G)
6 Y moving amount
designation
[], [] : Selects moving amount.
Set value: 1 mm – paper width (unit: 1 mm)
When media is not detected: 1 mm – Mechanical
limit size
7Cap OFF Only after media detection
8 Test start [ENTER]: Repeats the following motion with the designated
conditions.
(During the motion, No. of Y reciprocation is
displayed.)
a) Moves by Y designated distance.
b) Moves by X designated distance, and moves to Y
starting position.
9 End [END] :Returns to the motion starting position and executes
capping to end the test.
MAINTENANCE MANUAL > Test Items > Test Function > [MOTOR TEST] XY SERVO MOTOR
Model
TS34-1800A
Issued
2011.10.17
Revised F/W ver
1.20
Remark
1.0
Rev.

Other manuals for MIMAKI TS34-1800A