© 2011 MIMAKI ENGINEERING CO.,LTD.
1.1.2 P.1
1
2
3
4
5
6
7
8
MAINTENANCE MANUAL > Operating Principle > Basic Operation > Sub Switch Power ON
Model
TS34-1800A
Issued
2011.10.17
Revised F/W ver.
1.20
Remark
1.0
R.1.0
1.1.2 Sub Switch Power ON
Indication on LCD
Processing sequence
Step
Processing Description
Indication
on LCD
1 Initial setting of CPU and H/W
2 Display at sub switch power ON 1. [PLEASE WAIT] is displayed.
3 Voltage check 1. Check the power supply voltage on the main PCB assy.
• In the malfunction, [ERROR03 POWER **V] is displayed and the
system goes down.
4 FPGA setting 1. Execute the configuration of PDC and HDC.
• In the malfunction, [ERROR09 FPGA ERROR] is displayed and
the system goes down.
• When the fuse F13 of the main PCB assy is blown, the system shuts
down, displaying [ERROR205 42V HEAD VOLTAGE].
5 Version information display 1. Machine model name and main body firmware version are displayed.
2. “Revision” and “Boot/PDC/HDC version” are also displayed during
the service mode.
3. Special key function is workable during the version information is
being displayed. (Except firmware update)
6 Initial operation of the machine 1. See "1.1.3 Initial Machine Operation".
PLEASE WAIT TS34-1800A V*.** TS34-1800A V*.**.0
B*.**P*.**H**.**
B: Boot, P: PDC, H: HDC
Display at sub switch power ON Version information display Version information display
(during the service mode)