- 19 -
8. Set the register mark detection area on the operation panel of UCJV300/150.
(1) Press the [MENU]([FUNC1] key) in LOCAL mode.
(2) Press [][] key to select [CUTTING], and press the [ENTER] key.
(3) Select [MARK DETECTION], and press the [ENTER] key.
(4) Press the [FUNC3] key.
(5) Press the [][] key to set the following items, and press the [ENTER] key.
SCAN DIRECTION, FEED DIRECTION, and OFFSET X of [DETECT AREA] are as follows.
Item Value Set value
DETECT AREA -
You can configure various settings for the register mark
operation.
SCAN DIR.
DEFAULT,
0 cm,
5 cm to the device
width
Configure the detection width for the scanning direction. The
register mark is detected while scanning is performed bidi-
rectionally at the set detection width.
DEFAULT: The register mark is detected at half the media width.
0 cm: The register mark is detected only in the feed (media feed)
direction.
5 cm to the device width: The register mark is detected with the set
width.
FEED DIR.
10 to 50 cm
Set the detection distance in the feed (media feed) direction.
OFFSET X
0 to 100 cm
Set the Detection start position after the ID Cut.
FEED DIR.
Detection start position
SCAN DIR.
OFFSET X
Register markscanning path
The ID Cut end position for
the data immediately before.
[Front]
[Rear]