Chapter 4 Maintenance
4-21
1
2
2
4
5
6
Replacing the mist filter
1
Press the
(MENU)
in LOCAL mode.
2
Press to select “
MAINTENANCE
”,
and press the key.
• MAINTENANCE MENU will be displayed.
3
Press the key.
• “STATION” will be selected.
4
Press the key.
• “CARRIGE OUT” will be selected and the carriage
will move.
5
Open the left maintenance cover.
6
Remove the mist filter.
• Mist filters are located in two places.
• To remove the mist filter, pull the knob to the front
while pushing the hook in the direction indicated
by the arrow.
7
Replace with a new filter.
8
Insert the mist filter.
9
Close the maintenance cover, and press
the key.
• After its initial operation, the machine returns to
LOCAL.
Replacing the mist filter box
Replace it if it is badly scratched or dirty.
1
Press the
(MENU)
in LOCAL mode.
2
Press to select “
MAINTENANCE
”,
and press the key.
• MAINTENANCE MENU will be displayed.
3
Press the key.
• “STATION” will be selected.
4
Press the key.
• “CARRIGE OUT” will be selected and the carriage
will move.
5
Open the left maintenance cover.
6
Remove the mist filter box.
• To remove the mist filter, pull the knob to the front
while pushing the tabs in the direction indicated
by the arrow.
7
Remove the mist filter.
• If the filter is dirty, press it with a paper towel to
remove the dirt. Or replace it with a new mist filter
(SPC-0819).