In case the print does not improve
If the print does not improve after head cleaning ( Operation ManualP.2-28), clean the wiper.
The examples of defective printing
Improper head discharge caused by dust affects the drawing as follows.
Not to use in this condition, check the nozzle condition periodically before or during drawing.
The nozzle condition can be confirmed with [test print] of this machine.
When cleaning, be sure to put on the supplied goggles and gloves since you may get ink in
your eyes.
Tools
Wiper Sponge
(SPC-0578)
UJ Cleaning swab
(SPC-0386)
Gloves Goggles
Deflection Nozzle clogging
Ink drippling Sprayed ink