EasyManua.ls Logo

Mindeo ES4650 - Codabar

Mindeo ES4650
123 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
3-20 Codabar
Read:
Format
Start character
Data digits (variable)
Check digit (optional)
End character
Check digit verification: The check digit is made as the sum module 16 of the numerical value of the
data digits.
Check digit trans.: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of 3-16 Code 39 (Code 32, Trioptic Code 39).
Code ID setting: Refer to Code ID setting of 3-11 UPC-A.
Insertion group selection: Refer to Insertion group selection of 3-11 UPC-A.
Start/End Type: Codabar has four pairs of Start/End Pattern; you may select one pair to match your
application.
Start/End transmission: Refer to Start/End transmission of 3-16 Code 39 (Code 32, Trioptic Code 39).
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode
must be the same.
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. entry
Read
Disable
00
Enable
01*
*
Check digit verification
Disable
00*
*
Enable
01
Check digit trans.
Disable
00*
*
Enable
01
Max. code length
00-99
00-99
00*
*
Min. code length
00-99
00-99
01*
*

Table of Contents