EasyManua.ls Logo

Minelab F3Ci - Opening the Detector Body

Minelab F3Ci
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F3Ci Service Manual
_______________________________________________________________________________________________________________________
13
3.1 Opening the Detector Body
a. In order to conduct repairs and replace many of the parts of this detector, the first step
will often be to open the detector body. Many sections of this manual will refer back to this
section.
b. The following procedure outlines the steps involved in opening the detector body:
Prepare a clean well lit workspace.
Turn the detector off and remove the batteries.
Remove the four screws from the top of the armrest and remove the armrest.
P
lace the detector on its right side with the ON/OFF knob uppermost and remove the
two screws (45mm) that secure the hinge cover. Figure 9.
Remove the hinge cover.
Unscrew and disconnect the coil plug.
Remove the two screws (35mm) from the shaft hinge. Figure 10.
Figure 8
: Removing the Armrest
Figure 9: Removing Hinge Cover
Coil
C
onnector

Other manuals for Minelab F3Ci

Related product manuals