SP1 20.3
20
20-5 TROUBLE SHOOTING GUIDE
This section gives some solutions to problems which may arise during machine use. Only intevene after having
throughly read the contents of this manual. For any further problems not included herein please contact the SCM
Technical Assistance Department.
TROUBLE
The machine does not start
CAUSE WHAT TO DO
No power on one phase or more phases Make sure that the 3 phases are hot
Fuses of auxiliary circuit to protect the 1- Close the housing; if the machine does not start:
transformer interrupted or housing of fuses 2- Open the housing
open 3- Check the fuses; if required replace them (a set of
fuses is supplied in the accessory bag)
Emergency button on Switch off the emergency button by turning it
Top hood open Close the top hood to action safety micro switch
Magnetothermic switched off Re-set magnetothermic placed inside electric housing
TROUBLE
The machine stops during the working
CAUSE WHAT TO DO
No power on one phase or more phases Make sure that the 3 phases are hot
Fuses of auxiliary circuit interrupted or 1- Close the housing; if the machine does not start,
housing of fuses open. open the housing and check the fuses; if
necessary replace them (a set of fuses is supplied
in the accessory bag).
Too heavy duty working for the motor Wait until the motor overload cutout placed inside
power or bad working conditions electrical cabinet is cool. Reset it after some minutes.
Check the cutterblock knives, grind or replace them.