EasyManua.ls Logo

Minolta EP1085 - Main Erase Lamp

Minolta EP1085
339 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 GENERAL, MECHANICAL/ELECTRICAL
98.04.24
M-62
1174SBM1700A
The Main Erase Lamp is turned ON to neutralize any surface potential remaining on the
surface of the PC Drum after cleaning.
The Main Erase Lamp consists of five tungsten-filament lamps mounted on a Board.
17 MAIN ERASE LAMP
Control Signal ON OFF WIRING DIAGRAM
LA2 PWB-A PJ10A-7 H L 2-I
1139M044AA
Mounting Bracket Main Erase Lamp LA2
Slit
PC Drum
1174M001AA
Mounting Bracket
Slit
Copier
Front Frame
Tungsten-Filament Lamp
1151T06MCA

Table of Contents

Other manuals for Minolta EP1085

Related product manuals