26
© 2015 Minuteman International, Inc.
X17 ECO CFS Carpet Extractor #988751UM Rev. * 04/15
Problem Possible Cause Remedy
Machine does not funcon
Power cord may be disconnected at the
twist lock or wall outlet.
Check connecons and reconnect if
necessary.
Wall outlet breaker may have tripped. Reset breaker.
No water dispensed from spray jets
Circuit breaker in handle tripped. Reset breaker.
Soluon tank in-line lter valve may be
closed.
Open valve.
Sprayjet Switch is in OFF (O) or AUX (II)
posion.
Flip sprayjet switch to ON (I) posion.
No water in soluon tank. Fill soluon tank.
Spray intermient or streaked
Soluon hoses may be clogged or kinked.
Check hose for clogs, remove any debris if
found. Replace kinked hose if found.
Soluon tank in-line lter valve may be
clogged.
Clean strainer thoroughly.
The spray jets may be clogged.
Remove the spray ps and clean as
required. Do not clean out the hole in
the jet with a pin or wire. This may cause
permanent damage.
Troubleshooting
Troubleshooting Guide
Caution! Unplug power cord before sevicing machine component.