(5) System errors (900 to 999)
Table 2.7 System Error List (900 to 999)
Control Mode
Error
Code
Positioning
Fixed-Pitch Feed
Speed
Speed/Position Switching
Speed Switching
Constant-Speed
JOG
Manual Pulse Generator
Zeroing
Position Follow-Up Control
OSC
Error Cause
Error
Processing
Corrective Action
900
• When the servo amplifier power is switched
ON, the motor type set in the "system
settings" differs from the motor type actually
installed.
(Checked only when using MR-J2S-B/
MR-J2-B)
• Correct the motor type setting in the
system settings.
901
• When the servo amplifier power is switched
ON, the motor travel value while the power
was OFF is found to have exceeded the
"Power of Allowed Traveling Points" setting
made in the system settings.
Further
operation is
impossible.
• Check the position.
Check the encoder battery.

Table of Contents

Other manuals for Mitsubishi Electric A173UHCPU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric A173UHCPU and is the answer not in the manual?

Mitsubishi Electric A173UHCPU Specifications

General IconGeneral
BrandMitsubishi Electric
ModelA173UHCPU
CategoryControl Unit
LanguageEnglish

Related product manuals