10-6. Checking Component Parts' Function
Part Name Checkpoints
Notes:
1. If the water ow rate is less than the minimum ow rate setting
of the ow sensor (default 5.0 L/min), the ow rate error will be
activated.
2. If the water ow rate exceeds 36.9 L/min, the ow speed will be
greater than 2.0 m/s, which could erode the pipes.
*1 Flow rate recommended for installation
*2 With bu󰀨er tank
*3 If you want to secure the maximum ow rate, please install an
additional pump.
L
Signal cable
3
3
Power cable
BROWN
PWM input signal
Feedback signal
Signal ref.
BLUE
BROWN
GREEN/
YELLOW
BLUE
BLACK
M
1~
N
<Figure 10.6.1>
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
<Figure 10.6.2>
ERSC series
Flow rate [L/min]
External static pressure [kPa]
Speed 5 (Default setting)
Speed 4
Speed 3
Speed 2
Speed 1
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
<Figure 10.6.3>
E*SD series
Flow rate [L/min]
External static pressure [kPa]
Speed 5 (Default setting)
Speed 4
Speed 3
Speed 2
Speed 1
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
<Figure 10.6.4>
ERSF series
Flow rate [L/min]
External static pressure [kPa]
Speed 5 (Default setting)
Speed 4
Speed 3
Speed 2
Speed 1
ERSE series
0.0
20.0
40.0
60.0
80.0
100.0
120.0
140.0
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0
Flow rate [L/min]
External static pressure [kPa]
Speed 5 (Default setting)
Speed 4
Speed 3
Speed 2
Speed 1
0.0
0.0
5.0
10.0
10.0 15.0
20.0
20.0 25.0
30.0
30.0 35.0
40.0
40.0 45.0
50.0
50.0
60.0
70.0
80.0
<Figure 10.6.5>
ERPX series
Flow rate [L/min]
External static pressure [kPa]
Speed 5 (Default setting)
Speed 4
Speed 3
Speed 2
Speed 1
Outdoor heat pump unit Water ow rate
range [L/min]
Recommended
ow [L/min] *1
Packaged
model
PUZ-WM50 6.5 - 14.3 9.0
PUZ-WM60 8.6 - 17.2 10.8
PUZ-WM85 10.8 - 24.4 *3 15.2
PUZ-WM112 14.4 - 32.1 *3 20.1 *2
PUZ-HWM140 17.9 - 36.9 *3 25.1 *2
PUZ-WZ50 6.5 - 14.3 9.0
PUZ-WZ60 6.5 - 17.2 10.8
PUZ-WZ80 6.5 - 22.9 14.3
Split model
SUZ series
SUZ-SWM30VA 6.5 - 11.4 7.2
SUZ-SWM40VA2 6.5 - 11.4 7.2
SUZ-SWM60VA2 7.2 - 17.2 10.8
SUZ-SWM80VA(H)2 10.8 - 21.5 13.4
SUZ-SWM100VA(H) 10.8 - 25.8 *3 16.1
SUZ-SHWM30VAH 6.5 - 11.4 7.2
SUZ-SHWM40VAH 6.5 - 17.2 7.2
SUZ-SHWM60VAH 8.6 - 21.5 10.8
Split model
PUZ series
PUZ-S(H)WM60 7.2 - 22.9 10.8
PUZ-S(H)WM80 7.2 - 22.9 14.3
PUZ-S(H)WM100 7.2 - 28.7 17.9
PUZ-S(H)WM120 10.0 - 34.4 *3 21.5 *2
PUZ-S(H)WM140 10.0 - 34.4 *3 25.1 *2
Split model
Multi series
PUMY-P112 17.9 - 35.8 *3 25.1 *2
PUMY-P125 17.9 - 35.8 *3 28.7 *2
PUMY-P140 17.9 - 35.8 *3 29.6 *2
PXZ-4F75VG 11.5 - 21.7 13.4
PXZ-5F85VG 11.5 - 24.6 *3 15.2
<Table 10.6.1>
58
<Recommended water ow rate range>
<Water Circulation Pump Characteristics>
Note: For installation of E*PX series, set its pump speed with a pressure drop between
the hydrobox and the outdoor unit factored into the external static pressure.
OCH815A