108
12 REMOTE OPERATION
12.3 Remote RESET
Precautions
When keeping in forced ON or OFF status in advance
When keeping in forced ON or OFF status in advance, interlock using the PAUSE contact (SM204).
12.3 Remote RESET
This is an operation to reset the CPU module by an external operation when the CPU module is in the STOP status. In
addition, even if the RUN/STOP/RESET switch of the CPU module is set to RUN position, reset is possible when the CPU
module has stopped due to occurrence of an error that can be detected by self-diagnosis function.
Application of remote RESET
When a CPU module is in an inaccessible place and an error has occurred, CPU module can be reset by a remote operation.
Enabling remote RESET
To remotely RESET, remote RESET must be enabled.
Navigation window [Parameter] [FX5UCPU] [CPU Parameter] "Operation Related Setting" "Remote Reset
Setting"
Window
Displayed items
Method of execution of remote RESET
The following are the methods of execution of remote RESET.
Engineering tool method
Refer to the following.
GX Works3 Operating Manual
Item Description Setting range Default
Remote Reset Set whether or not to enable remote RESET. Disable
Enable
Disable
SM204
M0
Y72
Turns ON in PAUSE status.
SM204X0
Y71
Turns OFF in PAUSE status.
M20
Y70
The ON/OFF status of Y70 is determined by
the ON/OFF status of M20 in PAUSE status.