2. Operation Messages on Setting And Display Unit
2.1 Operation Errors
I - 47
2. Operation Messages on Setting And Display Unit
If a setting operation error occurs on any setting and display unit screen‚ the error No. EOO and a message
describing the details of the error will display in the line above the data setting area or the menu display
area.
2.1 Operation Errors
: Message requiring resetting and restarting
×: Message requiring restarting after canceling error conditions
(The bold characters are the messages displayed on the screen.)
Error No. Error message Details
E01 SETTING ERROR
The setting data is incorrect. An alphabetic character was set
when only number can be set‚ etc.
Data was input without setting number (#).
(Word editing)
Even though no retrieval data was set, menu key [ ] or [ ] was
pressed.
Even though no data is stored in edit buffers, menu key
“Replace” was pressed.
One of the following characters was entered as the first character
of the retrieval data and edit buffers: 0 to 9, ". ", " " (space), "+",
"", "=","*", "[ ]", and “ " " ”.
When the incremental detection system was used, the
parameter (#0 absolute position setting) was set on the absolute
position setting screen.
The data input for the standard parameter setting or during
execution of formatting is not "Y" or "N".
A value from 4 to 10 was specified for #1043 lang. Or 21 was
specified.
Even though no language data exists, its output and comparison
were attempted. Check the numbers (0253 and 0254) of the
language data to be output.
When the machine manufacturer macro program memory area is
the SRAM area, the setup parameter #1060 SETUP was set to
“20”.
When the machine manufacturer macro program memory area is
the SRAM area, writing of the machine manufacturer macro
program was attempted on PROGRAM COPY screen.

Table of Contents

Other manuals for Mitsubishi Electric MELDAS 60 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MELDAS 60 Series and is the answer not in the manual?

Mitsubishi Electric MELDAS 60 Series Specifications

General IconGeneral
Control TypeCNC
Spindle ControlYes
Series60 Series
InterpolationLinear and circular
DisplayLCD
Communication InterfaceRS-232
Memory CapacityVaries depending on model
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 60°C