APPX
Appendix 1 Checking Production Information and Firmware Version
153
A
Precautions
Check the target model and obtain the firmware update file that matches with the target model from your local Mitsubishi
representative. The firmware update cannot be executed if the firmware update file does not match with the target model.
Do not modify the data (folder name and file name) obtained from your local Mitsubishi representative.
Do not power off or reset the CPU module during execution of the firmware update. If the CPU module is powered off or
reset before the firmware update is finished, execute the firmware update again.
Do not remove the SD memory card from the CPU module during execution of the firmware update. If the SD memory card
is removed from the CPU module before the firmware update is finished, the firmware update may fail.
Troubleshooting
If the firmware update failed and an error code is stored in SD922 and SD933, check the following and take a necessary
action for troubleshooting.
If the firmware update fails even after the items above are checked and the actions are taken, the possible cause is a
hardware failure. Please consult your local Mitsubishi representative.
Error
code
Error name Error definition and cause LED status Action
READY PROGRAM
RUN
ERROR
0100H Flash ROM error Failed to access the flash ROM of
the CPU module.
Off Off Flashing Execute the firmware update
function again.
0200H Model mismatched The firmware update file that does
not match with the target CPU
module was used.
On Off Flashing Check the target CPU module and
execute the firmware update
function again.
0201H File invalid The invalid firmware update file was
used.
Write the firmware update file to the
SD memory card again.
Do not change the file name of the
firmware update file.
0203H Firmware update
prohibited state
The firmware update was prohibited
by the firmware update prohibition
file.
Confirm that the firmware update is
not prohibited and can be executed.
0300H Firmware data
error
An firmware data error was detected
during execution of the firmware
update function.
Flashing Off Flashing Execute the firmware update
function again.