5 SAFETY APPLICATION CONFIGURATION EXAMPLES
5.2 System to Which Multiple Safety CPUs are Connected
Setting details of device/label memory areas
Open the detailed settings window from the [Detailed Setting] for the [Device Setting]. Then set the safety device points on the
following window. Set number of points so that the total of the points will not exceed the capacity of the device area. Set the
parameters. Then, click the [Apply] button in the lower right of the window.
For details on parameter setting method, refer to the following.
GX Works3 Operating Manual
MELSEC iQ-R CPU Module User's Manual (Application)
Window
Displayed items
*1 When selecting 12K points, check the versions of the CPU module and the engineering tool. ( MELSEC iQ-R CPU Module User's
Manual (Application))
Item Setting (default)
Safety Input (SA\X) 8K points (either 8K or 12K points can be selected.)
*1
Safety Output (SA\Y) 8K points (either 8K or 12K points can be selected.)
*1
Safety Internal Relay (SA\M) 6K points
Safety Link Relay (SA\B) 4K points
Safety Timer (SA\T) 512 points
Safety Retentive Timer (SA\ST) 0 point
Safety Counter (SA\C) 512 points
Safety Data Register (SA\D) 12K points
Safety Link Register (SA\W) 4K points