27 TROUBLESHOOTING
27.4 Error Code List
7FE7H Remote password
error
The remote password is
not registered.
The remote password
processing command was
received on the interface
side where the modem
function is not used.
The MELSOFT
Connection is selected in
the Communication
protocol setting for the
corresponding channel.
A remote password
processing command is not
necessary when a remote
password is not registered.
Unlock the remote password
by MELSOFT. Alternatively,
change the Communication
protocol setting for the
corresponding channel to MC
protocol.
7FE8H Remote password
error
The number of remote
password mismatch
exceeded the designated
value of the address
200DH.
CHn
ERR.
Clear the 'accumulated count
of unlock process abnormal
completion' (Un\G8956) to '0'.
7FE9H Modem function
error
The number of callback
denial exceeded the
designated value of
address 2002H.
CHn
ERR.
Clear the callback denial
accumulated count (address:
22F1H) to '0'.

7FECH Module extended
parameters do
not exist.
Reading data has failed
since module extended
parameters do not exist.
Write module extended
parameters to C24 or CPU
module.
7FEDH Simultaneous
execution error
More than one target
device accessed to the
parameter file at the same
time.
CHn
ERR.
Do not access to the
parameter file from more than
one target device
simultaneously.
7FEFH Parameter setting
error
The parameter settings
with MELSOFT are
incorrect.
CHn
ERR.
Correct the parameter
settings, write it to the CPU
module, and restart it.

7FF0H Dedicated
instructions
simultaneous
execution error
Dedicated instructions
were executed
simultaneously.
Do not execute the dedicated
instructions simultaneously.

7FF1H Control data error Setting value is incorrect.
Setting value is out of the
range.
Correct the setting value in the
control data.

7FF2H Communication
protocol setting
error
The instruction cannot be
executed with the current
communication protocol.
Correct the setting value of
the communication protocol.

7FF3H to
7FF4H
System error The operating system of
C24 detected some error.
Page 490 Corrective actions
for system error
7FF5H Transmission
cancel at mode
switching/
transmission
sequence
initialization
The processing in
operation was cancelled due
to performance of the
following functions:
Mode switching,
transmission sequence
initialization, receive data
clear (by buffer memory),
user frame use enable/
disable designation, UINI
instruction, programmable
controller CPU
information clear
Do not execute these
functions during various
processes in progress.

7FF7H Simultaneous
access error
Multiple target devices
accessed to a station on
the same network at the
same time.
Do not access to a station on
the same network from
multiple target device at the
same time.
7FFBH Channel error Incorrect channel was
designated with a
dedicated instruction.
Review the channel for a
dedicated instruction.

Error code
(hexadecima
l)
Error Description Signal
name
Corrective action Protocol
MC Nonpr
ocedu
ral
Bidire
ctiona
l
Prede
fined