7 REPLACEMENT OF PROGRAM
7 - 13
(1) Performing the QCPU programming using GX Developer as a programming tool has following
restrictions.
(2) To use the existing A/QnACPU program with GX Works2, follow the procedure below.
(a) A/QnACPU program conversion procedure
(b) Conversion procedure of the difference information embedded Q program (A/QnA-Q
conversion support tool)
(c) Conversion procedure of the MELSECNET (II) local station dedicated module link refresh
program (A/QnA-Q conversion support tool)
• Model of available CPU module: QCPUs excluding High-speed Universal model QCPU
When this restriction applies, use GX Works2 as a programming tool.
1) Read project data from the existing A/QnACPU using GX Developer and save the file.

2) By using "Change PLC type", convert the read A/QnACPU program to a Universal model QCPU, which can be
specified with GX Developer.

3) Read the converted QCPU program by other format read ([Project] - [Open Other Data] - [Open Other Project]) of
GX Works2.

4) After that, configure various settings and modify the program using GX Works2.
1)
Read project data from the existing A/QnACPU using GX Developer and save the file.

2)
By using "Change PLC type", convert the read A/QnACPU program to a Universal model QCPU, which can be
specified with GX Developer, and save it.

3) Output the difference information embedded Q program and the review information list using the A/QnA-Q
conversion support tool.

4) Modify the difference information embedded Q program with GX Developer while referring to the review
information list.

5)
Read the difference information embedded Q program by other format read ([Project] - [Open Other Data] -
[Open Other Project]) of GX Works2.

6) After that, configure various settings and modify the program using GX Works2.
1)
Using the A/QnA-Q conversion support tool, set the output type of CPU to a Universal model QCPU and output
the MELSECNET (II) local station dedicated module link refresh program.

2)
Read the MELSECNET (II) local station dedicated module link refresh program by other format read ([Project] -
[Open Other Data] - [Open Other Project]) of GX Works2.

3) After that, configure various settings and modify the program using GX Works2.