7 REPLACEMENT OF PROGRAM
7 - 39
(b) AnSCPU timer ladder programming method
Set the total number of points of timer, and the first device number of low-speed timer, high-speed
timer and retentive timer in the Device setting of the parameter setting.
The default setting is as follows:
Number of points of timer: 256
First device number of low-speed timer: 0 (T0 to T199)
First device number of high-speed timer: 200 (T200 to T255)
First device number of retentive timer: 0
When using the retentive timer, change the setting to reserve necessary number of points.
7.7.5 Counter
7.7.6 Display instructions
Function QnUCPU/QnASCPU
AnSCPU
AnUS(H)CPU
A2ASCPU
AnS(J)HCPU
Specifying method
Updating present value
• When executing the OUT Cn instruction • When executing the END instruction
On/off processing for contact
Instruction QnUCPU QnASCPU
AnSCPU
AnUS(H)CPU
A2ASCPU
AnS(J)HCPU
PR
Not applicable for the Universal
model QCPU.
Consider using a display unit or
touch panel.
• With SM701 off: Outputs
characters before 00
H
.
• With SM701 on: Outputs 16
characters.
• With M9049 off: Outputs
characters before 00
H
.
• With M9049 on: Outputs 16
characters.
PRC
• With SM701 off: Outputs
comments in 32 characters.
• With SM701 on: Outputs first 16
characters of comment.
• Outputs comment in 16
characters.
C0
K100
C0
K100