7 REPLACEMENT OF PROGRAM
7 - 35
7.7.1 List of applicable devices
7.7 Precautions for Program Replacement
Device name QCPU QnASCPU AnSCPU
Number of I/O points
*7
Q03UDV
Q04UDV
Q06UDV
4096points
Q00UJ: 256 points
Q00U: 1024 points
Q01U: 1024 points
Q2AS: 512 points
Q2AS-S1: 1024 points
Q2ASH: 512 points
Q2ASH-S1: 1024
points
A2US: 512 points
A2US-S1: 1024 points
A2USH-S1: 1024
points
A2AS: 512 points
A2AS-S1: 1024 points
A2AS-S30: 1024 points
A1SJH: 256 points
A1SH: 256 points
A2SH: 512 points
Q02U, Q03UD(E),
Q04UD(E)H,
Q06UD(E)H
4096
points
*8
Number of I/O device
points
*6
8192 points 8192 points 2048 points
Internal relay
Q03UDV: 9216 points
Q04/06UDV: 15360 points
8192 points
*1
8192 points
*1
Total 8192 points
Total 2048 points
Latch relay
8192 points
*1
8192 points
*1
Step relay
Sequence
program
––
SFC 8192 points 8192 points
Annunciator
2048 points
*1
2048 points
*1
2048 points 256 points
Edge relay
2048 points
*1
2048 points
*1
Link relay
8192 points
*1
8192 points
*1
8192 points 1024 points
Link special relay 2048 points 2048 points 56 points
Timer
2048 points
*1
2048 points
*1
Total 2048 points Total 256 points
Retentive timer
0 point
*1
0 points
*1
Counter
1024 points
*1
1024 points
*1
1024 points 256 points
Data register
Q03UDV: 13312 points
Q04/06UDV: 22528 points
12288 points
*1
12288 points
*1
8192 points 1024 points
Link register
8192 points
*1
8192 points
*1
8192 points 1024 points
Link special register 2048 points 2048 points 56 points
Function input
16 points: (FX0 to FXF)
*5
16 points (FX0 to
FXF)
*5
Function output
16 points: (FY0 to FYF)
*5
16 points (FY0 to
FYF)
*5
Special relay 2048 points 2048 points 256 points
Function registers 5 points: (FD0 to FD4) 5 points (FD0 to FD4)
Special register 2048 points 2048 points 256 points
Link direct device
For CC-Link IE, MELSECNET/H
J\X, J\Y, J\W, J\B,
J\SW, J\SB
Specified from J\
Intelligent function module
device
Specified from U\G Specified from U\G
Index register
Z 20 points: (Z0 to Z19) 16 points (Z0 to Z15) 7 points (Z, Z1 to Z6) 1 point (Z)
V
*2
7 points (V, V1 to V6) 1 point (V)
File register
32768 points/block
*4 *9
(R0 to R32767)
32768 points/block
(R0 to R32767)
8192 points/block
(R0 to R8191)
Extended data register
*1
0 point
Extended link register
*1
0 point
Accumulator
*3
2 points
Nesting 15 points 15 points 8 points
Pointer 4096 points
4096 points
*11
4096 points 256 points
Interrupt pointer 256 points
256 points
*12
48 points 32 points
SFC block device 320 points
320 points
*10
320 points
SFC transition device 512 points/block
Decimal constant K-2147483648 to K2147483647 K-2147483648 to K2147483647
Hexadecimal constant H0 to HFFFFFFFF H0 to HFFFFFFFF
Real constant E±1.17550–38 to E±3.40282+38
E±1.17550–38 to
E±3.40282+38
Character string
"QCPU", "ABCD"
*4
"QnACPU", "ABCD"