18
*1 Put the SSCNET cable in the duct or fix the cable at the closest part to the Motion controller with bundle
material in order to prevent SSCNET cable from putting its own weight on SSCNET connector.
*2 Be sure to use the cable for forced stop input. The forced stop cannot be released without using it.
If the cable for forced stop input is fabricated on the customer side, make it within 30m (98.43ft.).
*3 Be sure to set the battery. The data in the RAM built-in Motion controller is not backed up if the battery cable is
not set correctly.
*4 Purchase the M5 screws.
(20) Memory card EJECT
button
Used to eject the memory card from the Motion controller.
(21) Memory card loading
connector
Connector used to load the memory card to the Motion controller.
(22) Battery connector Connector to connect the Q6BAT.
(23) Battery holder
*3
Battery holder to set the Q6BAT.
(24) Module fixing screw
hole
*4
Hole for screw used to fix to the control panel.
(25) FG terminal Ground terminal connected with the shield pattern of the printed circuit board.
(26) Extension cable
connector
Connector for connecting an extension cable (for signal communications with the
extension base unit).
No. Name Application