5 - 54
5 POSITIONING DEDICATED SIGNALS
(a) The flag turns off if a speed change request occurs during deceleration to a
stop due to speed change "0".
Start accept flag
Speed change "0"
accepting flag
OFF
ON
V
V
1
V
2
t
Speed change "0"
Speed change V
2
(b) The flag turns off if a stop cause occurs after speed change "0" accept.
Start accept flag
Speed change "0"
accepting flag
OFF
ON
V
t
Speed change "0"
Stop cause
(c) The speed change "0" accepting flag does not turn on if a speed change "0"
occurs after an automatic deceleration start.
Start accept flag
Speed change "0"
acce
p
tin
g
fla
g
V
t
Speed change "0"
(OFF)
Automatic deceleration start