EasyManua.ls Logo

Mitsubishi Electric Q172CPU - Page 277

Mitsubishi Electric Q172CPU
634 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - 16
7 MOTION PROGRAMS FOR POSITIONING CONTROL
(b) Constant-speed operation
100. 200.
FIN signal
(M3219+20n)
M-code outputting
(M2419+20n)
M-code
10
OFF
OFF
ON
ON
When the FIN signal (M3219+20n) is turned from OFF to ON to OFF during
positioning in block 2), the axis performs constant-speed operation without
decelerating stop in the block of M-code.
(6) The M-codes except the M00, M01, M02, M30, M98, M99 and M100 are output to
the M-code storage registers (D13+20n) of all axes specified at the program start.
However, the M-code storage register is not output to the axis in execution of
high-speed oscillation. Also, if the FIN signal (M3219+20n) is set to the axis in
execution of high-speed oscillation is invalid.
(Program No. 1 is started with X (axis 1) and Y (axis 2) specified
"SVST J1J2 K1" )
O0001;
N1 G25 X START90. STRK10. F30;
N2 G00 Y10. M77;
N3 G26 X;
M02;
%
X-axis high-speed oscillation start
PTP positioning of Y-axis
X-axis high-speed oscillation stop
M-code data
Invalid for X-axis
Unchanged (M-code not output to X)
G00 Y10. M77
Not turned ON for X-axis
G25
G26 X;
To next block
FIN signal
M-code outputting
signal
M2419
M2439
M3219
M3239
D13
D33
X-axis
Y-axis
77
ON
ON
OFF
OFF
OFF
OFF
ON