EasyManua.ls Logo

Mitsubishi Electric Q172CPU - Page 345

Mitsubishi Electric Q172CPU
634 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - 84
7 MOTION PROGRAMS FOR POSITIONING CONTROL
[Program Example]
The program in which the X-axis oscillates in the Sine curve of 10[mm] amplitude, 90
[degree] starting angle and 30[CPM] frequency.
(Command unit is [mm].)
G25 X START 90. STRK 10. F30 ;
(Note) : The starting angle (START) is valid to the first decimal place.
[Example] (1) START 90. .............. Means 90.0[degree].
(2) START 90 .............. Means 9.0[degree].
(3) In START #2010
#2010 = 900 ............... Means 90.0[degree].
#2010 = 1 ................... Means 0.1 [degree].

Table of Contents

Other manuals for Mitsubishi Electric Q172CPU

Related product manuals