2.6.2
Precautions regardiw.the
system
configuration
(1)
The only calculator link modules or serial communication modules which can be connected
and monitored are those listed below.
AJ71UC24
AJ71 C24-S8
(if
the CW to which the connection is being made
is
mu,
the device range
AiSJ7IUC24-R4
which can be monitored is the
ADA
range)
AJ71 QC24-R4
A1 -971 QC24
(2) The GOT can only be connected
to
one calculator link module/serial communications mod-
ule, in a 1
-to-I
configuration.
The GOT cannot be connected to a calculator link module/serial communications module in
an
n-to-1
configuration.
Exan&
of
connecting
a
GOT
and
calculator
link
module
Example
of
connecting
a
GOT
and
serial
com-
municatimodule
(3) The table below shows the connectors, crimping terminals, and cables used when connect-
ing the GOT and calculator link module with the following cables: A7GT-AC30R4, A7GT-
AC100R4, A7GT-AC300R4.
(a) Connection diagram
2-7