12
WT07627X03
Setting item Description LCD
Initial Setting
Tool
Web Browser for
Initial Settings
Function
settings
Set Temperature Range
Limit
Set to restrict the local remote
controller set temperature range.
V
Night Mode (quiet operation)
Schedule
Set to switch outdoor units to quiet
operation for a certain period of
time.
V
System-changeover
Set to automatically switch indoor
unit operation mode (heating
and cooling) based upon room
temperature and set temperatures.
V
External Temperature
Interlock
Set to interlock the temperature
differential between the set
temperature and the outdoor air
temperature to use automatic
adjustment.
V V
Night Setback Control
Set to automatically cool or heat if
the indoor temperature goes outside
a set range at night.
V V
Interlock control
Set interlock restrictions for interlock
operation when conditions have
been met.
V
*6 *6
AHC Port Name settings
Advanced HVAC CONTROLLER
(AHC) port name can be set.
V
Night purge
Set night purge to bring in cooler
outside night air.
V V
BACnet
®
*2
BACnet
®
objects can be set.
Floor settings
Floor settings
Set monitoring by displaying the
floor layout using the LCD.
V V
Floor settings for Integrated
Centralized Control Web
Set monitoring by displaying the
floor layout using the Integrated
Centralized Control Web.
V
Billing
function
settings
Billing Function settings
Apportioned electricity billing
function settings can be made.
V
*1
Outdoor Unit settings
Set outdoor unit parameters for
electric energy apportionment.
V
*1
Indoor Unit settings
Set indoor unit parameters for
electric energy apportionment.
V
*1
Measurement settings
Set connection relationship for
electric energy apportionment
metering devices and units.
V
*1
Charges settings
Time period setting for the seasonal
charges can be made.
V
*1
User settings
User settings for LCD
Set functions and passwords
that can be used with the LCD.
(Maintenance user/building
manager)
V
User settings for Integrated
Centralized Control Web
*3
Set general user and tenant
manager settings for Integrated
Centralized Control Web.
Maintenance
Data back-up/import
Save settings data to a USB
memory device. Also, this can
write settings data saved on
a USB memory device to the
AE-200/AE-50/EW-50 to restore
status.
V V
Software update
Update AE-200/AE-50/EW-50
software.
V V
Others
Check sheet for air-
conditioner ON/OFF trial run
A check sheet to be used for air
conditioning unit trial run can be
output.
V
*1 For details, refer to the Instruction Book (Apportioned Electricity Billing Function).
*2 Make the settings on the BACnet
®
Setting Tool. Refer to the Instruction Book (BACnet
®
Setting Tool).
*3 Make the settings on the Integrated Centralized Control Web. Refer to the Instruction Book (Integrated Centralized Control Web).
*4 LAN2 IP address (IPv4) for BACnet
®
can be set. IP address (IPv6) can be set only from the BACnet
®
Setting Tool.
*5 “Energy Management License Pack” is required. (AE-200E/AE-50E/EW-50E only)
*6 “Interlock control” license is required. On version 7.50 and later, make the settings from the Initial Setting Tool.