EasyManua.ls Logo

Mitsubishi FX3U-20SSC-H - 1. Introduction; 1.1 Outline of Positioning Block

Mitsubishi FX3U-20SSC-H
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mitsubishi Electric Europe B.V. /// FA-European Business Group /// Gothaer Strasse 8 /// D-40880 Ratingen /// Germany
Tel: (02102) 4860 /// Fax: (02102) 486112 /// Email:info@mitsubishi-automation.com /// Web: www.mitsubishi-automation.com
Issue:
February 2007 /// Created by: FA-EBG Marketing Communications Dept
Servo /// Motion /// Servo /// Motion /// Servo /// Motion /// Servo /// Motion /// Servo
2) Using GX Developer, write the servo parameters to the F3U-20SSC-H Flash ROM.
Open GX Developer and create a new FX3U project. To access the BFM, open the
Buffer memory batch window by going to [Online Monitor Buffer memory
batch].
Access BFM #522 by inputting ‘0’ for the ‘Module start address’ and ‘522’ for the
‘Buffer memory address’ as shown below. Note, the ‘Module start address’ is
different if you have other hardware connected to the FX3U.
1) Module start address: 0
2) Buffer memory address: 522
3) Click on the ‘Start monitor’ button.
4) Click on the ‘Device test’ button.

Other manuals for Mitsubishi FX3U-20SSC-H