GENERAL COOLING SYSTEM
COOLING SYSTEM
25 GENERAL
25.1 Specifications
1
1. All specifications are subject to change without any prior
notice
Description Specification
FAN BELT Standard type for industrial application LL HM type, length 905 mm [35.6299 in.]
COOLING FAN
L2: Standard type for industrial
application
4-blade or 5-blade, unequal pitch, pusher or suction type,
ø 290 [11.4173 in.]
L3: Standard type for industrial
application
5-blade or 6-blade, unequal pitch, pusher or suction type,
ø320 mm [12.5984 in.]
WATER PUMP Type Centrifugal impeller
THERMOSTAT
Type Wax pellet type
Valve opening temperature 76.5±1.5°C [169.7±2.7°F]
Full-opening temperature 90°C [194°F] (Valve lift 6 mm [0.2362 in.] )
THERMOSWITCH
Standard type Bi-metal type
Switch-ON temperature 111±3.5°C [231.8±6.3°F]
TEMPERATURE
GAGE UNIT
Gage specification
70°C [158°F]/104±13.5 W
115°C [239°F]/23.8±2.5 W
Voltage used 12 volt DC
Table 45 Specifications