Service Manual Mitsubishi L-Series diesel engines
Version 08/2004
SPECIFICATIONS AND MAINTENANCE
STANDARDS
ENGLISH
SERVICE SPECIFICATIONS AND
STANDARDS
Unit: mm (in.)
Description Specification and Standard Repair Limit Service Limit
Glow plug indicator (Quick-heat type) for L3
Type Red-hot type
Model DH-139V-29
Rated current 29A
Voltage across terminals (at 29A) 1.7V±0.2V
Fuel cutoff solenoid
Type Electromagnetic ETS push type
Coil resistance 1.6 ±10% (at 20°C [68°F])
Working voltage 10 to 15V DC
Stroke 10±0.5 [0.3937±0.0197]
Temperature range –30 to 120°C [–22 to 248°F]
Fuel cutoff solenoid
Type Electromagnetic ETR pull type
Rated voltage 12V DC
Rated temperature 20°C [68°F]
Coil resistance Pull 0.25 ±10% Hold 13.5 ±10%
Rated pull current 55A
Rated hold current 1A
Control timer
Input voltage 9V to 15V DC
Load Solenoid (Coil resistance 1.7 or more)
Working temperature –30 to 80°C [–22 to176°F]
Glow timer
Model S81NJ
Rated voltage 12V DC
Working temperature –40 to 85°C [–40 to 185°F]
Initial characteristic
(Normal temperature, normal
humidity, Vcc = 12V)
6 sec.
Environmental characteristic
(–30°C to 70°C [–22°F to 158°F],
Vcc = 7 to 15V)
6 sec.
Glow relay
Model G71S P
Rated voltage 12 V DC
Continous rating 1 minute
Coil resistance 13
Inductance 24 mH (at 1 KHz)
Working temperature -40 to 100°C [-40 to 212°F]
(70 to 100°C [158 to 212°F] for 20 sec. or less
continued use)
+1.4
-0
+2.0
-0.6