5. PARAMETERS
5 - 55
Control
mode
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
P S T
PF25
CVAT
SEMI-F47
function -
Instantaneous
power failure
detection time
Set the time of the [AL. 10.1 Voltage drop in the control circuit power] occurrence.
To disable the parameter, set "Disabled (_ 0 _ _)" of "SEMI-F47 function selection"
in [Pr. PA20].
Setting range: 30 to 200
200
[ms]
PF31
FRIC
Machine
diagnosis
function -
Friction
judgement
speed
Set a (linear) servo motor speed that divides a friction estimation area into high and
low during the friction estimation process of the machine diagnosis.
Setting "0" will set a value half of the rated speed.
When your operation pattern is under the rated speed, we recommend that you set a
half value of the maximum speed.
Forward rotation
direction
(Positive direction)
0 r/min
Operation pattern
[Pr. PF31] setting
Maximum speed in operation
Servo motor
s
peed
(Linear servo
motor speed)
Reverse rotation
direction
(Negative direction)
(0 mm/s)
Setting range: 0 to permissible speed
0
[r/min]/
[mm/s]