6. NORMAL GAIN ADJUSTMENT
6 - 4
The following parameters are set automatically with one-touch tuning. Also, "Gain adjustment mode
selection" in [Pr. PA08] will be "2 gain adjustment mode 2 (_ _ _ 4)" automatically. Other parameters will
be set to an optimum value depending on the setting of [Pr. PA09 Auto tuning response].
Table 6.1 List of parameters automatically set with one-touch tuning
Parameter Symbol Name Parameter Symbol Name
PA08 ATU Auto tuning mode PB18 LPF Low-pass filter setting
PA09 RSP Auto tuning response
PB19 VRF11
Vibration suppression control 1 -
Vibration frequency
PB01 FILT Adaptive tuning mode (adaptive filter II)
PB02 VRFT
Vibration suppression control tuning
mode (advanced vibration suppression
control II)
PB20 VRF12
Vibration suppression control 1 -
Resonance frequency
PB21 VRF13
Vibration suppression control 1 -
Vibration frequency damping
PB06 GD2 Load to motor inertia ratio
PB07 PG1 Model loop gain
PB22 VRF14
Vibration suppression control 1 -
Resonance frequency damping
PB08 PG2 Position loop gain
PB09 VG2 Speed loop gain PB23 VFBF Low-pass filter selection
PB10 VIC Speed integral compensation PB46 NH3 Machine resonance suppression filter 3
PB12 OVA Overshoot amount compensation PB47 NHQ3 Notch shape selection 3
PB13 NH1 Machine resonance suppression filter 1 PB48 NH4 Machine resonance suppression filter 4
PB14 NHQ1 Notch shape selection 1 PB49 NHQ4 Notch shape selection 4
PB15 NH2 Machine resonance suppression filter 2 PB51 NHQ5 Notch shape selection 5
PB16 NHQ2 Notch shape selection 2 PE41 EOP3 Function selection E-3
PB17 NHF Shaft resonance suppression filter