EasyManua.ls Logo

Mitsubishi MR-JE-200B - Junction Terminal Block PS7 DW-20 V14 B-F (Recommended)

Mitsubishi MR-JE-200B
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 17
11.3 Junction terminal block PS7DW-20V14B-F (recommended)
(1) Usage
Always use the junction terminal block (PS7DW-20V14B-F (Toho Technology)) with the option cable
(MR-J2HBUS_M) as a set. A connection example is shown below.
Junction terminal block
PS7DW-20V14B-F
CN3
MR-J2HBUS_M
Servo amplifier
Cable clamp
(AERSBAN-ESET)
Ground the junction terminal block cable on the junction terminal block side with the supplied cable
clamp fitting (AERSBAN-ESET). For the use of the cable clamp fitting, refer to section 11.10, (2) (c).
(2) Connection diagram of MR-J2HBUS_M cable and junction terminal block
1
2
DOCOM 3
4
8
7
9
SD
Shell
(Note) MR-J2HBUS_M
5
6
10DICOM
11
12
MBR 13
14
18
17
19
15
16
20EM2
Shell Shell Shell
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
DOCOM
SD
DICOM
MBR
EM2
E
Servo amplifier
CN3
Junction terminal block
PS7DW-20V14B-F
Connector: 52316-2019 (Molex)
Shell kit: 52370-2070 (Molex)
CN Terminal block
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
Note.