9 - 9 9 - 9
MELSEC-Q
9 PROGRAMMING
(b) When setting is completed with an error
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Y8
X8
XA
X9
X0
OFF
ON
X3
OFF
ON
Executed by QJ71MT91
Executed by sequence program
0C13
H
0C14
H
to 0C15
H
ON
Parameter creation
Module READY
Basic parameter
setting existence
R
MODBUS device
assignment
parameter setting
request
R
MODBUS device
assignment
parameter setting,
normally completed
R
MODBUS device
assignment
parameter setting,
error completed
R
MODBUS device
assignment
parameter setting
existence
R
MODBUS device
assignment
parameter error code
storage area
R
MODBUS device
assignment
parameter setting
result storage area
R
MODBUS device
assignment
parameter
correction
R
MODBUS device
assignment
parameter
creation (error)
R
MODBUS device
assignment parameter
setting, normally
completed
R
MODBUS device
assignment parameter
setting, error
completed
Error code
and setting
result clear
Error code
and setting
result storage