EasyManua.ls Logo

MIXER PLUS Series - Page 24

MIXER PLUS Series
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual instruction Mixer Plus Mixer Technology srl pag.24
The recommend pressure depend from plaster types and from the second tube length
according to the following scheme:
o Cement type = 1 bar/metro
o Gaseous type = 0,8 bar/metro
Example: for processing gaseous type with the 15 meters tube the maximum
recommend pressure is 15 x 0,8 = 12 bar.
IT’S ABSOLUTELY FORBIDDEN TO USE THE MACHINE WITH MATERIAL
OUTPUT PRESSURE VALUES GREATER THAN 20 BAR