Manual instruction Mixer Plus Mixer Technology srl pag.26
CLEANING OF CHAMBER MIXING
1) Only for mod. PLUS-MONO: Remove the gearmotor power supply outlet;
2) The machine can be externally cleaned with a sponge or damp cloth;
3) Open the gearmotor mixing assembly (see figure below);
4) Extract the mixer and clean it with the metallic brush (standard supplied);
5) Insert the rod in the cleaning device;
6) Manually insert the rod and cleaning device in the mixing chamber by
rotating manually the rod till it is connected into the radial cavity of the
rotor; N.B: Rotate the gearmotor joint coupling till the rod matches the
end;
7) Close the gearmotor assembly and hook it up;
8) Insert the power supply plug of the mixing gearmotor;
9) Start the mixer;
10) After 10 s (time cleaning necessary) stop the mixer;
11) Extract the cleaning device and the rod following the reverse procedure.