Manual instruction Mixer Plus Mixer Technology srl pag.27
CLEANING OF THE HOPPER
At each change of the product used, it is suggested to perform the cleaning of the
hopper:
1) Place a suitable container under the hopper drain door and open this latter
(fig.1-14);
2) Remove the gearmotor power supply outlet (only mod. Plus Mono);
3) Disconnect the water tube from the trunket (fig. 1-11-12);
4) Open mixer assembly;
5) Rotate the gearmotor assembly flange clockwise;
6) Extract the mixer from the mixing chamber;
7) Stop and halt gearmotor assembly;
8) Open the mixing chamber locking lever(fig.1-3);
9) Remove the water tube to mixing chamber;
10) Rotate the mixing chamber, lifting it up from below;
11) Insert a sheet of paper or polypropylene between the hopper and the mixing
chamber;
12) Lower the mixing chamber and close the mixing chamber locking lever;
13) Reconnect the conveying water tube to mixing chamber;
14) Start the cell dosing wheel until the complete emptying of hopper;
15) Close the hopper drain door;
16) Open the mixing chamber and remove the sheet of paper or polypropylene;
17) Insert the mixer in the mixing chamber and connect it into the radial cavity of
the rotor;
18) Rotate the gearmotor assembly flange counter-clockwise, until correspond with
the mixer;
19) Close and stop the mixing gearmotor assembly;
20) Connect the water tube to mixing chamber.