Take the 3 observations of the points carefully from at least 3 camera positions. Best practice
are 4 to 6 (image above shows 5 camera positions with a variation of camera angles and
distances to the points) .
For the best calibration, each point should be seen from a variety of angles and distances. If you
know where the studio cameras will operate and where the set is, you can focus your
observations from these positions.
12.5 Calibration and Application
Once you are happy with the observations made, click on Osets → AutoAligner → Params All
buttons should be o, except Stage 1, Stage 2 and Fix Linear should be on. Fix Linear locks CCD
osets. Make sure you measured them accurately and entered them accurately into the TP
oset elds in Osets menu before performing an AutoAlign.