104
Display Operating Procedure
Description
“Technical” Programming
Filter Alarm
• This parameter enables the technician
to program an alarm that will alert the
user about the need for maintenance or
replacement of the water lter.
• Once the set volume has been reached,
the error message “Filter Alarm” will be
displayed.
• A value of 0 (zero) disables the lter
alarm parameter.
• This feature can be enabled or disabled.
Enter Password
Filter Alarm
Settings
Enter Password
1
After accessing the “Technical” programming menu and entering the password, use the buttons T1 and T2
until the following screen is displayed.
Filter Alarm
Settings
2
Press the T3 button to enter the menu.
Filter Alarm
ENABLED
3
Press the T3 button to enter the menu, move between the parameters using the buttons T1 and T2 to
select ENABLED or DISABLED , press the T3 button to conrm the option.
Filter Status
0 of 5000L
Filter Alarm
5000 Liters
4
Press the T3 button to enter the menu, move between the parameters with the buttons T1 and T2 to
set the desired value, press the T3 button to conrm the value.