EasyManua.ls Logo

modbar av Series - Page 83

modbar av Series
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
83
Display
Operating Procedure
Description
“Technical” Programming
(only on ABR espresso machine models)
Enter Password
Scale
Configuration
Scale Configuration
This parameter allows the operator to
view and manually change each dose for
each Selection Indicator.
For greater accuracy and consistency of
the doses, it is recommended that you
set each Selection Indicator.
The dose can be set by pulses or by
mass (weight).
This parameter enables the technician
to set some scale parameters like:
- Enabling/disabling the offset
parameter;
- Setting the weight reading time;
- Calibrating the scales;
- Updating the scale software.
Enter Password
1
After accessing the “Technical” programming menu and entering the password, use the buttons T1 and T2
until the following screen is displayed.
Scale
Configuration
2
Press the T3 button to start the doses programming procedure.
Auto Offset
ENABLED
3
Press the T3 button to enter the menu, move between the parameters using the buttons T1 and T2
to select ENABLED or DISABLED, press the T3 button to conrm the option.
Scale Tare Time
3s
4
Press the T3 button to enter the menu, navigate the parameters using the buttons T1 and T2 to set the
desired value. This parameter is common to all groups.

Related product manuals