RESEARCH AND DEVELOPMENT
15
5) Place the machine back in the correct position and remove the upper and side sheet steel
cover, making sure not to pull the electric wires. Then remove the thermal insulation
without breaking it.
6) Unscrew the bracket securing the heating element probe and pull it off. Position the new
heating element probe and remount the anchoring bracket.
IMPORTANT: make sure that the tip of the probe is pushed into contact with the heating
element as shown in the photo below. The probe must remain at distance from the sheet
metal of the cavity.