Terminals
23
10/04 AWB2528-1548GB
Removing the power supply/communication module
Use a screwdriver with a 100 x 3.5 mm slot width.
X Insert the screwdriver into the lug of the fixing shaft
catch.
X Lever out the slide catch.
X Pull out the power supply/CPU module from the fixing
shafts.
Figure 16: Releasing the fixing shaft
Terminals Terminals
The MFD-CP4 is fitted with cage clamp terminals for
connecting the power supply and the connection cable to the
serial interface.
Tool for cage clamp terminals
Slot-head screwdriver, width 3.5 mm x 0.6 mm.
Connection cross-sections of the MFD cage clamp
terminal cables
Power supply terminal:
0.08 to 2.5 mm
2
(AWG 28 – 12)
Interface terminal
0.14 to 0.5 mm
2
(AWG 26 – 20)
1
2
3
1
3
2