MC Series Brushless Driver User Manual
9
2023 - September version V1.2
Digital Hall supports up to 2.5 kHz switching frequency and 5 V logic level
Incremental encoder supports up to 16384 resolution
U, V, W three-phase winding
The motor is blocked for more than 2 seconds and the motor is
disabled.
If the current exceeds 15A or the set value, the system
automatically reduces PWM to reduce the current. If the
current still exceeds the limit after the duty cycle is reduced to
the minimum value, the driver alarms and stops working.
If the current exceeds the set current, the motor will be
disabled and an alarm will be issued.
Alarm when the working voltage is >55V, and restore when the
voltage drops to 50V
Alarm when the working voltage is less than 9.5V, and restore
when the voltage rises to 12V
The Hall sensor signal is lost or abnormal for 100ms and then
an alarm is issued
120x76x24.5mm (excluding connectors)
Operating ambient
temperature range
5% - 90% (no condensation)
Avoid dust, oil mist and corrosive gas