EasyManua.ls Logo

MORTEX E30 SERIES - Safety Precautions; General Safety Requirements; Signal Word Definitions; Hazard Warnings Explained

Default Icon
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Coil Cabinet
Model
Front Door
of Cabinet
Open Top 17 3/4in
(450.85m) x 21
3/4in (52.45m)
Maximum Air
Flow
CFM (L/s)
1 inPleated
Air Filter,
in the door
2 in Pleated
Air Filter,
Top of Cabinet
Height, In (m)
Depth,
In (m)
Width In
(m)
Coil Sizes
97-FLSB-21 Louvered N/A 120 (56.369) 20 x 20 23 1/4 (590.5) 25 (635) 19 3/4 (501.65)
All Mortex 96 series
coil will fit in Cabinet
97-FSOB-21 Solid 160 (75.159) 20 x 24 23 1/4 (590.5) 25 (635) 19 3/4 (501.65)
97-FLOB-21 Louvered 180 (849.5054) 20 x 20 20 X 24 23 1/4 (590.5) 25 (635) 19 3/4 (501.65)
97-FLSB-27 Louvered N/A 160 (75.159) 20 x 30 30 1/2 (74.7) 25 (635) 19 3/4 (501.65)
96-97 series coil
and 98 series coil
sizes up to 98-8W7
97-FSOB-27 Solid 160 (75.159) 20 X 24 30 1/2 (74.7) 25 (635) 19 3/4 (501.65)
97-FLOB-27 Louvered 180 (849.5054) 20 x 20 20 X 24 30 1/2 (74.7) 25 (635) 19 3/4 (501.65)
97-FLSB-39 Louvered N/A 180 (849.5054) (2EA) 20 x 20 40 1/4 (1,02.35) 25 (635) 19 3/4 (501.65)
97FSOB-39 Solid 200 (943.8949) 20 X 24 40 1/4 (1,02.35) 25 (635) 19 3/4 (501.65)
Frame & Grilles
Non-Cabinet
97-FG-18 Louvered N/A 120 (56.369) N/A N/A 18 (457.2) N/A 19 3/4 (501.65)
97-FG-24 Louvered N/A 160 (75.159) N/A N/A 24 (609.6) N/A 19 3/4 (501.65)
Models ALL ALL ALL
Input kW 6 8 10
With “A Coil NO NO NO
Air Temperature Rise - F 30-90 35-100 40-100
Air Temperature Rise - C -1.1-32.2 1.6-37.7 4.4-37.7
Designed Max Outlet Air Temp, F/C 180 / 82.22 185 / 85 185 / 85
Blower Size 10 x 9 10 x 9 10 x 9
Max ESP In.W.C./kPa 0.3/0.075 0.3/0.075 0.3/0.075
Thermostat Circuit Electrical Specs. 24 VAC, 60 HZ, 40 VA
Electric Furnace Cabinet Height, In/cm 33 / 83.82 33 / 83.82 33 / 83.82
Models ALL ALL ALL
Input kW 12 15 20
With “A Coil NO NO NO
Air Temperature Rise - F 30-90 35-100 40-100
Air Temperature Rise - C 1.1-32.2 1.6-37.7 4.4-37.7
Designed Max Outlet Air Temp, F/C 180 / 82.22 185 / 85 185 / 85
Blower Size 10 x 9 10 x 9 10 x 9
Max ESP In.W.C./kPa 0.3/0.075 0.3/0.075 0.3/0.075
Thermostat Circuit Electrical Specs. 24 VAC, 60 HZ, 40 VA
Electric Furnace Cabinet Height, In/cm 33 / 83.82 33 / 83.82 33 / 83.82
E = Electric Furnace
30 = 33 Inches
D=Downow
Type
of Fuel
Cabinet
Height
Type of
Blower Motor
Blower Motor
Speed Taps,
HP and kW
Furnace
Conguration
Heating
Input
Cabinet
Height
Heat
Stage
Revision
Letter
B = Constant Torque
3 = 1/3 HP (0.1865kW)
5 SPD CT
4 = 1/2 HP (0.3730kW)
5 SPD CT
5 = 3/4 HP (0.5595kW)
D = D-Revision
A = Single Stage Heat
B = Two Stage Heat
A = Coil Cabinet Optional
006 = 6 kW Electric Heater
008 = 8 kW Electric Heater
010 = 10 kW Electric Heater
012 = 12 kW Electric Heater
015 = 15 kW Electric Heater
020 = 20 kW Electric Heater
MORTEX PRODUCTS INC. 501 TERMINAL RD FORT WORTH, TX 76106 Page 2
Figure 1: Electric Furnace Dimensions
Table 3: Optional Cooling Cabinets and Return Air Grille Frames
Table 2: Model Number Nomenclature
Table 1: Electric Furnace Specifications
Furnace Weights
E30B3DxxxA(A,B)D Models – 79 lbs. / 35.834 kg
E30B4DxxxA(A,B)D Models – 81 lbs. / 36.740 kg
E30B5DxxxA(A,B)D Models – 85 lbs. / 38.555 kg
Available Blower Motors
1. Standard Blower Motor - 5 SPD Constant Torque

Table of Contents

Other manuals for MORTEX E30 SERIES

Related product manuals