6. Close the window after upgrades is completed.
3.7
Manual IMPRES 2 or IMPRES Calibration and
Reconditioning
Though calibration or reconditioning is automatic, some situations require manual initiation. For example, the
IMPRES 2 or IMPRES charger indicates alternating amber and green LED for the IMPRES 2 or IMPRES
battery, because calibration is disabled in the charger. If within 30 minutes that battery is moved to an
IMPRES 2 or IMPRES charger that has calibration enabled, the last charging state will resume, preventing
automatic start of calibration or reconditioning.
ATTENTION: Manual calibration or reconditioning does not apply to IMPRES 2 batteries that have
icon.
3.7.1
Initiating Calibration or Reconditioning Manually
Prerequisites: Ensure that the IMPRES 2 or IMPRES battery is removed from the charger for more than 2.5
minutes.
Procedure:
1. Insert the battery into the charger pocket.
2. Within 2.5 minutes, remove the battery from the charger pocket.
3. Within 5 seconds, reinsert the battery into the charger pocket.
Result: Calibration or reconditioning starts immediately. Typically, it begins with battery discharge (steady
amber). Calibration or reconditioning is complete after full charge (steady green).