RxOverrun: displays the total number of receiver-overrun errors on the Ethernet controller.
Late Collision: displays the total number of late collisions on the Ethernet controller. A normal
collision occurs during the first 512 bits of the frame transmission. If a collision occurs after the 512
bit times, then it is considered a late collision. A late collision should be taken as a serious network
problem, since it causes the frame being transmitted to be discarded. The most common cause of
late collisions is a mismatch between duplex configurations at each end of a link segment.
RetransLimitExp: displays the total number of retransmit limit expirations.
TxUnderrun: displays the total number of transmission-underrun errors on the Ethernet controller.
CarSenseLost: displays the total number of carrier sense lost errors occurred on the Ethernet
controller.
EXPANDED STATS
Clicking on the
Expanded Stats
link will display a number of pages of statistics that are maintained
by the Canopy module. Canopy Technical Support may ask the operator for specific information in
this section when troubleshooting an issue.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola Canopy and is the answer not in the manual?

Motorola Canopy Specifications

General IconGeneral
ModelCanopy
DimensionsVaries by model
WeightVaries by model
Frequency Range2.4 GHz, 5.2 GHz, 5.4 GHz, 5.7 GHz, 900 MHz
ModulationOFDM
InterfaceEthernet
Power SupplyPoE

Related product manuals